ZLZanthera LabSilver shielding textiles
|

EU lab testing archive

EU lab testing status and product evidence.

Shielding effectiveness is measured with a coaxial method according to GB/T 30142-2013 and ASTM D4935: the textile sample sits in a controlled fixture between transmitting and receiving contacts, and the signal reduction is reported in dB by frequency.

EU attenuation lab test

Pending

Intertek Sweden. Report attaches at launch after final independent verification of the launch materials.

EU textile reference review

Available

SIMT 2019, GB/T 30142-2013 reference data.

FrequencyMeasured attenuation
30 MHz59.6 dB
100 MHz53.6 dB
300 MHz48.9 dB
1 GHz43.8 dB
3 GHz39.1 dB
6 GHz32.7 dB
10 GHz28.3 dB

Historical mill-lab reference, not a claim for current production.

EU restricted-substance screening

Pass

SGS SHAEC23002818401 (2023): lead, mercury, and cadmium ND; DEHP 130 mg/kg (< 1000 limit).

How we claim